Frequently Asked Questions

Can a cabinet unit heater be mounted on the ceiling?

Yes, the TPI 6300 Series Multiple Angle Cabinet Unit Heaters are listed for wall or ceiling mounting. They can be surface mounted, semi-recessed or fully recessed, and airflow is front in, front out. Recessed and semi-recessed installations are finished with TF-33 or TF-46 trim frames. Plan the opening and the electrical feed before the wall or ceiling is closed in.

What does 3/5 kW mean on a cabinet heater?

It means the heater has two heat settings. On low it produces 3 kW, about 10,200 BTU per hour, and on high it produces 5 kW, about 17,100 BTU per hour. The 6/10 kW models work the same way at roughly 20,500 and 34,100 BTU per hour. The blower also runs at two speeds to match the heat setting.

Does a cabinet unit heater need a separate wall thermostat?

The TPI 6300 Series models in this category have a built-in single-stage thermostat with relays, powered from an internal 24V source and adjustable from 40 to 110 degrees Fahrenheit. They also include a disconnect switch. For basic control you set the built-in thermostat and choose high or low operation. Check the installation instructions if your project calls for remote control.

What voltage cabinet heater do I need?

Match the heater to the building supply. The 6300 Series is offered at 208V and 240V, which are listed as 1/3 phase and can be wired for single or three-phase, and at 480V three-phase. Higher voltage draws fewer amps for the same output. A qualified electrician should confirm the voltage, phase and circuit size before you order.

How do I maintain a cabinet unit heater?

The TPI 6300 Series models include a dust filter. Inspect and clean or replace it on a regular schedule, especially in dusty spaces or entryways, so airflow stays strong. Keep the front intake and outlet grilles clear of furniture and stored items. Always turn off power at the disconnect before opening the cabinet, and follow the manufacturer's manual for service.

Cabinet Heaters

What a cabinet unit heater is

A cabinet unit heater is an electric heater with its element, blower and controls inside an enclosed metal cabinet. A fan draws room air in through a grille, passes it over the element and blows it back into the space. Cabinet heaters are common in entryways, corridors, lobbies and classrooms, where they mount on a wall or ceiling, out of the way of foot traffic.

TPI 6300 Series Multiple Angle Cabinet Unit Heaters

The cabinet heaters in this category are TPI 6300 Series models. TPI lists them for commercial and institutional buildings such as stores, schools, offices, transportation terminals, churches and entranceways. They mount on a wall or ceiling and can be surface mounted, semi-recessed or fully recessed. Airflow is front in, front out, with air entering and leaving through the face of the cabinet.

Each model has high and low settings for both heat and blower speed. The motor is a two-speed, shaded pole, resilient mounted, direct drive type. A disconnect switch, a dust filter and a beige powder-coated finish are listed on these models. Control is a built-in single-stage thermostat with relays, run from an internal 24V source, with a 40 to 110°F range.

Sizes and power options

Two output ranges are offered. The first number is the low heat setting and the second is the high setting.

  • 3/5 kW, 208V, 1/3 phase (6333D052033B30D0F)
  • 3/5 kW, 240V, 1/3 phase (6333D052433B30D0F)
  • 3/5 kW, 480V, three-phase (6333D054833B30D0F)
  • 6/10 kW, 240V, 1/3 phase (6346D102433B30D0F)
  • 6/10 kW, 480V, three-phase (6346D104833B30D0F)

Models marked 1/3 phase can be wired for either supply. The 208V listing notes that it is factory wired for three-phase and field convertible to single-phase with a 24V control circuit.

How to choose

Start with the building supply. Match voltage and phase first, since a 480V model will not run on 240V. Then size the output. One kilowatt of electric heat is about 3,413 BTU per hour, so a 5 kW setting delivers about 17,000 BTU and a 10 kW setting about 34,000 BTU. Entryways with frequent door openings and rooms with high heat loss need the larger size.

Next, decide how the cabinet will be installed. Surface mounting is the simplest. Recessed and semi-recessed installations need a wall or ceiling opening planned at rough-in, and TPI offers TF-33 and TF-46 trim frames to finish them. KB33, KB46 and KB79 kickbases stand a cabinet on a pedestal. Match the frame or kickbase size to the cabinet. These accessories are listed under heater mounts.

A qualified electrician should size the circuit and confirm local code requirements. For other ways to heat entries, shops and open areas, compare fan forced heaters or browse all heating equipment.