What are these heater mounts used for?

These heater mounts are used to install heating equipment securely to the wall or ceiling. Some are designed to suspend heaters on ceilings, beams, walls, or poles, while others are made to mount heaters into the recesses of walls for a seamless installation.

Where should I mount my heater?

Most heaters, like baseboards or convection heaters, are made to be mounted under windows. Downflow, fan, or cove heaters can be mounted on the ceiling or cove. Recessed and panel heaters need to be mounted flush to the wall or ceiling with recessing sleeves, rough-in boxes, or T-bar kits.

How do I mount a wall heater?

Check your manufacturer’s manual first before following this general heater installation guide:
  1. Mark the location on the wall where you plan to install your heater. It’s recommended to mount the heater between studs for better support.
  2. Drill into the places where your heater mounts will go. Make sure that they are perfectly level and aligned with your mounts.
  3. Screw the heater mounts into the drilled holes.
  4. Secure your heater to the mounts.

How do I know if my heater is compatible with any of these mounts?

Most of these heater mounts are made for specific heater models. Ask your manufacturer or refer to your manual first to see if your heater is compatible with any of these mounts. The compatible heater models are specified in these mounts’ descriptions, so you can refer to these descriptions as well.

What is the difference between recessed, semi-recessed and surface mounted wall heaters?

A recessed heater sits nearly flush in the wall cavity, usually in a rough-in wall box. A semi-recessed heater stands 1 or 2 inches proud of the wall on a recessing sleeve or extender. A surface mounted heater sits entirely on the wall face, using a surface frame that is 4 inches deep in TPI's range. Wall depth and appearance decide which one fits.

When should I use a pipe mount instead of a wall bracket?

TPI recommends wall brackets for buildings with substantial walls, where the arm can also be bolted to structural steel. Pipe mounting kits are for buildings without the structural strength for other mounts. The HLA Series and 5500 Series pipe kits require a 3 1/2 inch pipe, about 4 inches outside diameter, and the pipe is not supplied with the kit.

What is a T-bar mounting kit for a ceiling heater?

A T-bar kit lets a ceiling heater sit in a suspended grid ceiling in place of a ceiling tile, without cutting into a hard ceiling. TPI offers the TB3380, a 2x2 kit for 3380 Series commercial fan forced ceiling heaters, and the TB3000 frame for 3000 Series fan forced ceiling heaters. Match the kit to the heater series.

Do unit heater brackets fit every kW size?

No. TPI unit heater brackets are sized by kilowatt range as well as series. For example, the UHB-1 fits 3.3 to 15 kW UH Series heaters up to 11 inches wide, while the UHB-3 fits 20 to 30 kW models up to 17 inches wide. Check the kW rating on the heater nameplate before choosing a bracket.

What is a kickbase for a cabinet unit heater?

A kickbase is a pedestal that raises a cabinet heater off the floor. TPI sells the KB33, KB46 and KB79 for 6300 Series Multiple Angle Cabinet Unit Heaters in 33, 46 and 79 inch sizes. The kickbase is sold as the pedestal only, so the heater and any trim frame are separate items. Match the kickbase size to the cabinet.

Heater Mounts

Heater mounting hardware

Most electric heaters ship ready to wire but not ready to hang. The right bracket, frame or sleeve depends on the heater series, its kW rating, and whether it goes on a wall, a ceiling, a pipe or into a recess. This category lists TPI mounting hardware, and nearly every item names the series it fits.

Brackets for unit heaters

Fan forced unit heaters hang from walls, ceilings or structural steel, and their brackets are sized by kW:

  • 5100 Series horizontal or vertical unit heaters: A5105 and V5105 for 3.3 to 5 kW, B5105 for 3.3 to 20 kW, A5120 and V5120 for 7.5 to 20 kW, A5150 and B5150 for 25 to 50 kW, and A5175, B5175, A51100 and V51100 for suspended 60 to 100 kW models.
  • UH Series horizontal unit heaters: UHB-1 for 3.3 to 15 kW and UHB-3 for 20 to 30 kW.
  • 5500 Series washdown unit heaters: W5520/WMK wall and P5520/PMK pipe brackets for 3.3 to 15 kW, and W5550/WMK and P5550/PMK for 20 to 48 kW.
  • HLA Series hazardous location unit heaters: HLWM37, HLWM10 and HLWM1525 wall kits, and HLPM37, HLPM10 and HLPM1525 pipe kits.
  • Downflow unit heaters: A1600 ceiling bracket for 5 to 20 kW and A1601 for 25 to 50 kW.

TPI recommends wall brackets for buildings with substantial walls, and they can bolt to structural steel. Pipe kits are for buildings that lack the strength for other mounts. They require a 3 1/2 inch pipe, which is not supplied.

Frames, sleeves and boxes for wall heaters

Wall heaters can be recessed, semi-recessed or surface mounted. The Box 3420 rough-in wall box sets up a recessed 3420 Series heater. Semi-recessing sleeves and extenders hold the heater 1 or 2 inches off the wall, such as the 3420EX8 and 3420EX16 for the 3420 and 3450 Series, or the 4300EX16 and 4400EX16 for low profile models. Surface sleeves and frames give a 4 inch depth, such as the 3450EX34, 4400EX32, and 4300EX32 (ivory) or 4300EX32W (white). The 4300 Series wall plate adaptor comes in white, ivory and bronze.

Ceiling frames and cabinet heater accessories

For lay-in grid ceilings, the TB3000 T-bar frame fits 3000 Series fan forced ceiling heaters and the TB3380 2x2 kit fits the 3380 Series. Other ceiling items include the 3380EX33 surface adapter, the PT3480 recess frame for 3480 Series heaters, and SF200 and SF400 aluminum surface frames for 2x2 and 2x4 foot CP Series radiant ceiling panels. Mul-T-Mount infrared heaters recess with the RMF222A, RMF222SSA (stainless) or RMF342A frames. The 342 frame needs a 36 x 17 7/8 inch ceiling cutout. The FSS95TMK kit mounts two FSS Series flat panel infrared heaters together. For 6300 Series cabinet unit heaters, TF-33 and TF-46 trim frames finish recessed installs, and KB33, KB46 and KB79 kickbases stand the unit on a pedestal.

Choosing the right mount

Read the full model number and kW rating from the heater nameplate and match both to the listing. Then confirm the structure can carry the heater and choose wall, ceiling or pipe mounting to suit it. Shop the heaters in fan forced heaters and infrared heaters.